All questions

Florida Journeyman Practice Exam

Browse all practice questions for the Florida Journeyman Practice Exam. Search by topic, open any question and review its full explanation, then test yourself in the practice quiz.

Florida Journeyman Practice Exam 2026 – The Comprehensive All-in-One Guide to Master Your Certification! course image
All questions

These questions are part of the practice quiz. Start practicing

  • What is the difference between series and parallel circuits?
  • Which of the following is not a type of electrical wiring?
  • What is an electrical discharge?
  • What must all closed type hot water heating systems, not under continuous attendance, be provided with?
  • What is the purpose of a disconnect switch?
  • What is an acceptable method for scavenging the combustion chamber and breaching of a boiler?
  • What is the primary role of a surge protector?
  • Which of the following shall not be used for safety reasons within a refrigerant system for testing?
  • What should be used to cover air inlets from outside the building serving residential occupancies?
  • What is the maximum height for outdoor lighting installations?
  • What is the minimum thickness needed for a 14-inch round sheet metal duct used in a residence?
  • What is the most serious consequence of not removing all the nitrogen used for pressure testing on an HCFC system?
  • Insulation applied to an exterior surface of ducts in buildings other than dwelling or apartments shall have a flame spread rating of not more than?
  • What is the function of a relay in an electrical circuit?
  • What is the primary purpose of a ventilation system in a commercial kitchen?
  • According to NEC, how many receptacles are permitted per 20-amp circuit?
  • If a user finds that their refrigerant system is oversaturated, what is a likely contributing factor?
  • Which devices are used to convert alternating current (AC) to direct current (DC)?
  • What is the minimum unobstructed access width that must be provided on all sides of a boiler?
  • What is the function of a fuse in an electrical system?
  • What is the minimum spacing between rung cleats or steps of a fixed ladder at a construction site?
  • What is the minimum clearance required for overhead service wires over residential properties?
  • Which of the following is not a requirement for air dispersion system?
  • What is the required depth for underground electrical service conductors?
  • What could be caused by high head pressure in a refrigerant system?
  • What is the maximum height of a surface that an employee can work or walk above an adjoining?
  • What is the minimum width of a discharge opening for a grease duct serving a type one hood?
  • Which of these tapes is acceptable as a closure system for fibrous glass duct board?
  • Gas equipment is installed on a roof 4 feet from the edge of the roof, how high must the railing be?
  • What is the standard height for light switches in residential buildings?
  • A duct serving a type one grease hood that penetrates a ceiling, wall, or floor should be enclosed in a duct enclosure from which point?
  • Where should the main burner of a gas-fired boiler have an approved manual shut-off valve installed?
  • How many ohms is considered a low-resistance connection?
  • Which of the following is not an indication of a partial restriction on the high side of the refrigeration system?
  • What is the primary function of circuit breakers in electrical systems?
  • Which of the following is not a main type of automatic refrigerant flow control?
  • Condensate drain piping shall not be installed with a slope of less than?
  • What kind of ground is typically used for electrical devices in wet locations?
  • Which issues might originate from a compressor operating at reduced volumetric efficiency?
  • What should be monitored to ensure safe operation of gas-fired boilers?
  • What is a common effect of high pressure in the high side of a refrigeration system?
  • Which code specifies the standards for ventilation supply air?
  • What is the primary function of a thermostatic expansion valve in a refrigerant system?
  • What is the rated lifespan for most incandescent light bulbs?
  • If a compressor has a displacement of 10 cubic inches but actually pumps 6 cubic inches, what is its volumetric efficiency?
  • What type of screen is required for air inlets from outside the building serving residential occupancies?
  • What should be considered when installing outdoor wiring?
  • An outside air inlet for a non-residential portion of a building can have a screen with openings but must be smaller than what size?
  • Which valve is used to control the gas supply to the burners during operation of an appliance?
  • What is the primary function of a transformer?
  • What can appliance vent connectors and joints be securely joined with?
  • In a ducted system with a cooling coil installed and an existing furnace heat exchanger, where must the air first flow through according to code?
  • When an appliance with a combustible chamber is located in the same room as a ventilation system return air opening, how close should the return air be to the open combustion?
  • What is required for every automatic hot water heating boiler not under continuous attendance?
  • What is the minimum level of insulation required for a portion of supply duct greater than 3 inches in diameter on the exterior of a residential structure?
  • What is the purpose of a transformer?
  • What is the maximum outlet temperature limit for warm air in a plenum supplied by a furnace?
  • Which of the following factors is NOT a consideration in ventilation systems?
  • What impact does reducing the airflow across the evaporator have on the system?
  • A refrigerant system that has been improperly pressure-tested could lead to what type of operational issue?
  • What type of equipment cools by evaporation of water into an Airstream?
  • In a medium temperature application, how can heat transfer resistance in the evaporator be reduced?
  • What is the maximum allowable voltage drop for branch circuits?
  • Which of the following is not a main type of automatic refrigeration flow control?
  • How does a contactor operate?
  • What is the minimum area for vertical ducts delivering outside combustion air to a 45,000 BTU/h rated water heater?
  • What is the main benefit of a low water cutoff switch for a boiler?
  • What is the primary function of a receiver in a refrigerant system?
  • What does the term "conductor" mean in electrical terms?
  • For what purpose is a main disconnect switch installed in an electrical service?
  • What is a sign of a faulty transformer in an electrical circuit?
  • What is the purpose of bonding in electrical systems?
  • Which of the following is not acceptable material for the base of a boiler?
  • What color identifies a grounded conductor in electrical wiring?
  • How often must a residential electrical panel be inspected?
  • Which factor is not considered in ventilation systems?
  • Drainage and overflow from cooling towers and evaporated condensers may discharge into which of these areas?
  • A vertical duct delivers outside combustion air to a water heater. What is the minimum area of each duct if the water heater is rated at 45,000 btuh?
  • What is the purpose of the bleed port in a thermostatic expansion valve?
  • Which of the following is a primary function of an air handling unit in ventilation systems?
  • An outside air inlet serving a nonresidential portion of a building may be covered with a screen. The size of the opening in this screen mesh must be no smaller than what size?
  • Absorption refrigerating systems must not be located less than 20 feet from a door window or ventilating air inlet to any building unless what condition is met?
  • What does the term "ampacity" refer to?
  • What is typically used to limit the amount of current flowing in a circuit?
  • Which type of duct is typically used for exhaust purposes in commercial kitchens?
  • What must every fuel-burning heating appliance bear on a permanent and legible factory-applied nameplate?
  • What is required for every electrical service according to Florida code?
  • Condensate drain piping shall not be installed with a slope of less than?
  • A boiler furnishing steam air pressures in excess of 15 psi is classified as what?
  • What is the normal procedure for checking electrical circuits?
  • Which of these tapes is acceptable as a closure system for fibrous glass ductboard?
  • Where shall the main burner of a gas fired boiler have an approved manual shut off valve installed?
  • What is the purpose of a ground fault circuit interrupter (GFCI)?
  • What is the main purpose of a circuit breaker?
  • Which substance should not be used for safety reasons within a refrigerant system for testing?
  • What is the minimum clearance from a grease duct system to combustible material?
  • What is the primary purpose of grounding in electrical systems?
  • What should be the maximum number of lighting fixtures connected to a 20-amp circuit?
  • Where must a platform be provided for equipment in an attic installation?
  • What code must all new electrical installations comply with?
  • What does a wattmeter measure?
  • What is the minimum level of insulation that a portion of a supplied duct that is on an exterior of a residential structure requires if the duct is greater than 3 inches in diameter?
  • What is an ampere?
  • Which procedure is crucial before performing maintenance on a refrigeration system?
  • Which gas is commonly used for pressure testing refrigerant systems due to its safety?
  • What happens to the evaporator if a thermostatic expansion valve is oversized for a system?
  • In refrigerant systems, which system component governs the rate of refrigerant flow?
  • How many circuits can be placed on a 20-amp breaker in a residential setting?
  • What is the primary material used for electrical panel grounding?
  • What is the minimum ampacity requirement for home branch circuits?
  • What is the minimum thickness required for a 14" round sheet metal duct used in a residence?
  • What is the safe distance for installing outdoor electrical wiring above the ground?
  • What effect does a thermostatic expansion valve with a discharge power element have on the evaporator?
  • What does NEC stand for in the context of electrical standards?
  • What is the function of a grounding electrode system?
  • What is the minimum number of hours required for Journeyman Electrical Apprenticeship in Florida?
  • To check electrical circuits, how is a voltmeter usually connected?
  • What is the minimum clearance required to combustibles for duct systems operating between 125°F and 250°F?
  • What defines a "dedicated circuit"?
  • Which of the following is not a requirement for an air dispersion system?
  • Copper tubing used for refrigerant piping of mechanical refrigeration systems shall be commercially designated as?
  • Boilers shall be tested for carbon monoxide to what maximum level?
  • Which of the following is not acceptable material for the base of a boiler?
  • The components of a refrigeration system under evaporator pressure are referred to as what?
  • Why is it important to maintain proper distances from exhaust discharges in machinery rooms?
  • What is the purpose of a surge protective device?
  • What size breaker is required for a 12-gauge copper wire?
  • What would disallow duct from penetrating a third floor without a fire damper?
  • When installing receptacles, what is the required height from the floor?
  • What happens if the testing gas is not properly removed from a refrigerant system?
  • What instrument is used to measure airflow velocity?
  • Which statement about hearing protection for employees is true?
  • What type of equipment operates by cooling through the evaporation of water into the air system?
  • In a medium temperature application, the major resistance to heat transfer in the evaporator is the film of refrigerant oil. How may this be reduced?
  • Which type of lighting should be used in damp environments?
  • What type of exhaust is approved for connection to a 6" flue stack venting a gas-fired furnace?
  • What does adjusting the superheat primarily affect in a refrigeration system?
  • Which of the following is not a requirement for a fire damper?
  • Residential gas furnaces may be vented with single wall vent piping under all conditions except?
  • When removing any group 1 refrigerant except CO2 from a refrigeration system, how should it be discharged?
  • What is the minimum clearance to combustible materials for a duct system operating between 125 degrees and 250 degrees?
  • What is the first procedure to perform when starting up a new unit?
  • An established and recognized agency regularly engaged in conducting tests of furnishing inspection services when such agency has been approved by the building official is called?
  • What is the residential service voltage in most Florida homes?
  • If an appliance is installed to its listed clearance, what will the installation be considered?
  • Which component is typically used to interrupt power in an electrical service?
  • What electrical code section deals specifically with residential wiring?
  • What is the main advantage of using LED lighting?
  • What is the purpose of using an anemometer in refrigeration systems?
  • What does a voltmeter measure?
  • How high should the pan of batten seam roofs be turned?
  • What is a typical sign of a starved evaporator?
  • What is the outside sheet metal size of an insulated duct with an airside dimension of 18"x10" and 1" insulation?
  • When are junction boxes required in residential wiring?
  • Which device is most commonly used for protecting against electrical shocks in wet environments?
  • Which of the following is prohibited for mechanical refrigerating systems and portions thereof?
  • All of the following are indications of partial restriction on high side except?
  • What is the minimum thickness required for Type I commercial hoods made of stainless steel?
  • What type of pressure does an evaporator usually operate under?
  • What type of device uses a RCD to prevent electrical shock?
  • In a machinery room containing mechanical refrigerating equipment, what is the minimum distance required between the machinery room exhaust discharge and the exterior door or window?
  • An emergency refrigeration control switch is required to shut off all electrically operated machinery in what type of room?
  • What is a common indication of electrical overload?
  • What type of space is indirectly cooled and enclosed within the building's thermal envelope?
  • For safety reasons, which gas should not be used for testing refrigerant systems?
  • Why is it important to label circuit breakers in an electrical panel?
  • What type of ventilating equipment can be transported easily without dismantling and is not connected to a duct?
  • What is a common issue that can arise from improper duct sizing?
  • What is an established and recognized agency called that is engaged in conducting tests or furnishing inspection services?
  • What is the function of a capacitor in an electrical circuit?
  • Which Florida agency oversees licensing for electrical contractors?
  • According to regulations, the return air from a dwelling unit shall not be discharged through the cooling system to what?
  • What does the term "overcurrent" mean?
  • In an attic installation, where must a platform be provided?
  • What type of device protects sensitive electronics from power surges?
  • What type of labeling is required on refrigerant pressure relief devices?
  • The minimum spacing between rungs, cleats, or steps of a fixed ladder on a construction site shall be?
  • How often must residential smoke alarms be tested?
  • Which material is most commonly used for electrical conduit?
  • What is the maximum distance between outlets in a residential kitchen according to the NEC?
  • Which factors influence the selection of wire sizes in electrical installations?
  • A thermostat is a device that detects what condition?
  • What type of wire is typically used for residential wiring?
  • What is the flame spread rating limit for insulation applied to ducts in buildings other than dwellings or apartments?
  • Combustion air supply is required for which type of equipment?
  • What size wire is typically used for a 30-amp circuit?
  • What condition does a low water cutoff aim to prevent in a boiler?
  • Where must smoke alarms be installed in a home?
  • What electrical hazard is caused by aging wiring or insulation?
  • What does GFCI stand for in electrical systems?
  • An emergency refrigeration controls switch shall be provided to shut off all electrically operated machinery in any machinery room containing a mechanical refrigeration system. What may the switch not shut off?
  • In what conditions can electricians work on energized circuits?
  • Why must liquid and suction line piping be sized large enough?
  • Absorption systems use which type of refrigerant for better efficiency in certain conditions?
  • In refrigerant systems, excessive nitrogen can lead to which condition?
Subscribe